Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 308168954

Citation: 01001A

Citation Type: Serious

Abatement Status: X

Initial Penalty: $1,500.00

Current Penalty: $1,125.00

Issuance Date: 01/26/2005

Nr Instances: 1

Nr Exposed: 4

Abatement Date: 02/15/2005

Gravity: 03

Report ID: 0317900

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 02/09/2005 $1,125.00 02/15/2005 Serious  
Penalty Z: Issued 01/26/2005 $1,500.00 02/15/2005 Serious  

Text For Citation: 01 Item/Group: 001A Hazard: STRUCK BY

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Worksite, 930 East Market Street, Bethlehem PA - On or about December 21, 2004 at 15:40 hours employees engaged in roof truss installation were exposed to injury from being struck by the collapsing truss roof components as the trusses were not adequately stabilized with temporary bracing. Among other methods, one feasible and acceptable abatement method to correct this hazard is to utilize the recommendations of the Truss Plate Institute and Wood Truss Council of America contained on the BCSI-B1 Summary Sheet Guide for Handling, Installing and Bracing of Metal Plate Connected Wood Trusses. These recommendations would include but not be limited to the following: 1. Provide Top Cord Temporary Lateral Bracing a minimum of 4 feet on center as recommended in the BCSI-B1 Publication and figures B1-23 & B1-24. 2. Provide Top Cord Temporary Diagonal Bracing as recommended in the BCSI-B1 Publication and figures B1-24 3. Provide Bottom Cord Temporary/Permanent Lateral and Diagonal Bracing as recommended in the BCSI-B1 Publication and figures B1-25 & B1-26. 4. Provide Web Member Bracing as recommended in the BCSI-B1 Publication and figures B1-28. 5. Utilize a minimum of two 10d, 12d or 16d nails driven flush for all bracing and spacer attachments as required by BCSI-B1 Publication. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.tives

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close