Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 300099157

Citation: 01001A

Citation Type: Serious

Abatement Status: X

Initial Penalty: $5,000.00

Current Penalty: $2,500.00

Issuance Date: 01/11/1999

Nr Instances: 1

Nr Exposed: 2

Abatement Date: 01/15/1999

Gravity: 10

Report ID: 0112300

Contest Date:

Final Order:

Related Event Code (REC): R

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 02/04/1999 $2,500.00 01/15/1999 Serious  
Penalty Z: Issued 01/11/1999 $5,000.00 01/15/1999 Serious  

Text For Citation: 01 Item/Group: 001A Hazard: EXPLOSION

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to dangerous concentration of carbon monoxide: (a)201 Armistice Blvd. Pawtucket,RI: Employees working inside the building were exposed to excessive concentrations of carbon monoxide generated by a diesel powered Bob-Cat loader and two Liquefied Petroleum Gas concrete saws, which were intended for outdoor use only unless provided with exhaust ventilation to the outside. Five employees were overcome and treated at the scene and transported to the hospital. The fire department tested the air quality when they first arrived and found carbon monoxide levels in excess of 500 parts per million (PPM). The NIOSH exposure limit for carbon monoxide is 200 PPM (a maximum concentration not to be exceeded for any period of time). Among other methods, feasible and acceptable abatement methods to correct this hazard are: 1. Provide local exhaust ventilation to the concrete saw in accordance with the manufacturers direction. 2. Provide adequate general exhaust ventilation in the work area and monitor levels of carbon monoxide. 3,Utilize electric concrete saws inside a building or in an enclosed or confined work area. "ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM"

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close