Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 191046.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,000.00
Current Penalty: $4,550.00
Issuance Date: 03/23/2012
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 04/19/2012
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/19/2012 | $4,550.00 | Serious | ||
| Penalty | Z: Issued | 03/23/2012 | $7,000.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) National Electrical Carbon Products, Inc. dba Morgan AM&T - Fostoria, Ohio: On or about January 7, 2012, the employer did not assure the pulley(s) that moves the cloth laying machine's carriage was adequately guarded. An employee was injured when the employees hand became caught in the belt and pulley, resulting in an amputation injury. No additional abatement information is needed for this item.