Violation Detail
Standard Cited: 19260451 B05 II General requirements.
Inspection Nr: 1795112.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,965.00
Current Penalty: $2,400.00
Issuance Date: 05/13/2025
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/09/2025
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 07/15/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/15/2025 | $2,400.00 | 06/09/2025 | Serious | |
| Penalty | Z: Issued | 05/13/2025 | $4,965.00 | 06/09/2025 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a) On or about December 24, 2024, employees were working on a scaffold platform which extended over its support by approximately 25 inches and was not blocked with guardrails. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Translate