Violation Detail
Standard Cited: 19100132 D01 I General requirements.
Inspection Nr: 1791155.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,620.00
Current Penalty: $3,972.00
Issuance Date: 05/09/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/05/2025
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 05/29/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/29/2025 | $3,972.00 | 06/05/2025 | Serious | |
Penalty | Z: Issued | 05/09/2025 | $6,620.00 | 06/05/2025 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.132(d)(1)(i):The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: a.) Foam Room, Storflex Holdings, Inc., 392 West Pulteney St., Corning, NY 14830, on or about 12/3/2024; Employees were exposed to chemicals classified as sensitizers including, but not limited to, AUTOFROTH 100-B-1704 RESIN and AUTOFROTH 15000A ISOCYANATE, and the employer did not require them to wear gloves. Abatement certification is required.