Violation Detail
Standard Cited: 19100147 C07 III B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1786655.015
Citation: 01001A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $12,768.00
Current Penalty: $1,195.00
Issuance Date: 04/30/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/19/2025
Gravity: 5
Report ID: 0215800
Contest Date: 05/23/2025
Final Order: 08/08/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 08/08/2025 | $1,195.00 | 05/19/2025 | Other | |
| Penalty | C: Contested | 06/13/2025 | $12,768.00 | 05/19/2025 | Serious | |
| Penalty | Z: Issued | 04/30/2025 | $12,768.00 | 05/19/2025 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
1910.147(c)(7)(iii)(B) Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: a) On or about 11/5/2024, Production area: Employees were performing servicing and maintenance tasks without utilizing Lockout/Tagout procedures. This included , but is not limited to, inspecting the sensors of the Sumitomo Injection Molding Machine. Lockout/Tagout training was not provided to authorized employees. Abatement certification is required for this item.
Translate