Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1784951.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,744.00
Current Penalty: $12,744.00
Issuance Date: 03/07/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/23/2025
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 05/23/2025
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 03/07/2025 | $12,744.00 | 04/23/2025 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Warehouse floor/ Packaging Department - On or about 10/18/2024, the employer exposed employees to amputation hazards and electrical shock hazards in that, the employer failed to ensure the hazardous energy control lockout/tagout procedures were developed, documented, and implemented for the employees during servicing and maintenance of equipment, such as but not limited to clearing jams from the Fam Cutter.
Translate