Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1783708.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,340.00
Current Penalty: $7,404.00
Issuance Date: 12/17/2024
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 06/27/2025
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 01/16/2025
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/16/2025 | $7,404.00 | 06/27/2025 | Serious | |
| Penalty | Z: Issued | 12/17/2024 | $12,340.00 | 01/02/2025 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Gel room and hot extrusion packaging area; On or about October 18, 2024, and dates prior, energy control procedure(s) were not developed, documented, and utilized before employees performed covered activities such as but not limited to assembly, cleaning, and debris removal on the REB Inc. model SVS piston filler machines.