Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1781707.015
Citation: 01001A
Citation Type: Serious
Abatement Status:
Initial Penalty: $14,895.00
Current Penalty: $12,660.00
Issuance Date: 03/13/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/30/2025
Gravity: 10
Report ID: 0523300
Contest Date:
Final Order: 04/08/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/08/2025 | $12,660.00 | 06/30/2025 | Serious | |
Penalty | Z: Issued | 03/13/2025 | $14,895.00 | 03/21/2025 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about October 4, 2024, the 2189 Pointer machine (S/N PP-456) hazardous energy control procedure was not utilized when an employee was changing a set of dies.