Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1777914.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,627.00
Current Penalty: $2,813.50
Issuance Date: 01/17/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/06/2025
Gravity: 5
Report ID: 0112300
Contest Date:
Final Order: 02/05/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/05/2025 | $2,813.50 | 03/06/2025 | Serious | |
| Penalty | Z: Issued | 01/17/2025 | $5,627.00 | 03/06/2025 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. a) M59 Machine #367: On or about September 26, 2024, an employee was exposed to ingoing nip points on the M59 Machine #367 when Lockout Tagout was not utilized during servicing or maintenance activities.