Violation Detail
Standard Cited: 19261053 A17 Ladders.
Inspection Nr: 1765124.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 03/05/2025 2
Initial Penalty: $6,452.00
Current Penalty: $3,871.20
Issuance Date: 01/15/2025
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 10
Report ID: 0419730
Contest Date:
Final Order: 02/11/2025
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/11/2025 | $3,871.20 | 03/05/2025 | Serious | |
Penalty | Z: Issued | 01/15/2025 | $6,452.00 | 03/05/2025 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.1053(a)(17): Fixed ladder(s) without a cage or well did not have a clear width to the nearest permanent object of at least 15 inches (38 cm) on each side of the centerline of the ladder: a. On or about July 26, 2024, at the east side of the building, the employer exposed employees and contractors to an approximately 14-foot fall hazard, in that; employees were allowed to climb up and down a fixed ladder with a handrail obstructing the first two rungs.