Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1751336.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,231.00
Current Penalty: $2,115.50
Issuance Date: 08/28/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/15/2024
Gravity: 5
Report ID: 0112300
Contest Date:
Final Order: 09/19/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/19/2024 | $2,115.50 | 10/15/2024 | Serious | |
| Penalty | Z: Issued | 08/28/2024 | $4,231.00 | 10/15/2024 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. a) Jobsite: On or about 5/30/2024, the employer failed to conduct periodic inspections of each energy control procedure at least annually to verify that the specific procedures for equipment, such as the Gardener Double Disc Grinder, were adequate and being applied correctly.