Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1721997.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $0.00
Issuance Date: 07/12/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/28/2024
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 08/05/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/05/2024 | $0.00 | 08/28/2024 | Serious | |
Penalty | Z: Issued | 07/12/2024 | $16,131.00 | 08/28/2024 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy. (a) On or about January 17, 2024, located at 7323 Omega Circle, Franksville, WI 53126, employees were conducting maintenance and servicing work on a waste collection vehicle to identify and repair a leak. The employer did not ensure the documented energy control procedures included rules and techniques for employees to utilize when re-energizing the vehicle to perform diagnostic testing, thereby exposing employees to caught-in hazards while reaching in and around rotating parts.