Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1702800.015
Citation: 01001A
Citation Type: Serious
Abatement Status:
Initial Penalty: $10,046.00
Current Penalty: $0.00
Issuance Date: 12/07/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/29/2023
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 01/05/2024
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/05/2024 | $0.00 | 12/29/2023 | Serious | |
Penalty | Z: Issued | 12/07/2023 | $10,046.00 | 12/29/2023 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). (a) #7 Silo 2nd Floor: On October 5, 2023, and times prior to, employees attempting to correct a plugging issue on the #7 silo did not de-energize the screw conveyor auger motor using the energy isolating device, exposing employees to two moving belts and two rotating sheaves.