Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1701641.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,813.00
Current Penalty: $3,908.00
Issuance Date: 01/10/2024
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 02/09/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/09/2024 | $3,908.00 | Serious | ||
| Penalty | Z: Issued | 01/10/2024 | $7,813.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.134(f)(2):Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: a) Divine Rehabilitation and Nursing at Shane Hill located at 10731 State Route 118 in Rockford, Ohio; On or about October 5, 2023, and at times thereafter, the employer did not provide a fit test to employees required to don N95 filtering facepiece respirators annually. The employer required employees to wear N95 filtering facepiece respirators to protect against the SARs-CoV-2 virus while providing care such as, but not limited to, bathing, feeding, and dressing, residents suspected or confirmed positive with COVID-19.