Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1677432.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $15,625.00
Current Penalty: $7,812.50
Issuance Date: 09/21/2023
Nr Instances: 1
Nr Exposed: 15
Abatement Date: 05/01/2024
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 10/19/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/19/2023 | $7,812.50 | 05/01/2024 | Serious | |
Penalty | Z: Issued | 09/21/2023 | $15,625.00 | 10/18/2023 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) projected more than one half the diameter of the shaft: a) A-4 Slice Line: On or about June 15, 2023, employees were exposed to unguarded, rotating shaft ends, located approximately two feet above ground level and adjacent to the walkway along the process line.