Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1667266.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $15,625.00
Current Penalty: $7,813.00
Issuance Date: 06/30/2023
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 07/25/2023
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 07/28/2023
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/28/2023 | $7,813.00 | 07/25/2023 | Serious | |
Penalty | Z: Issued | 06/30/2023 | $15,625.00 | 07/25/2023 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. 1). Whirlpool Corporation, on or about April 27, 2023 at the address of 1300 Marion-Agosta Road, Marion OH 43302: The employer failed to develop, document and utilize a energy control procedure to control potentially hazardous energy for die tool 799. The employee was removing a jammed part from die tool 799, position D6, without the benefit of fully controlling all potentially hazardous energy. Due to this condition, the employee was exposed to a crush/pinch point hazard and sustained an amputation to their left middle finger.