Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1661222.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,162.00
Current Penalty: $5,000.00
Issuance Date: 06/23/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 07/27/2023
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 07/11/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/11/2023 | $5,000.00 | 07/27/2023 | Serious | |
Penalty | Z: Issued | 06/23/2023 | $11,162.00 | 07/27/2023 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: (a) Building 5, Prep Area: On April 27, 2023 and times prior, employees were required to wear 3M 8210V tight fitting N95 particulate respirators while performing chipping and grinding operations on precast concrete buildings to protect employees from respirable crystalline silica. The employer has not ensured that the employees were fit tested prior to the required respirator use.