Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1631826.015
Citation: 01001A
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $10,046.00
Current Penalty: $4,018.00
Issuance Date: 02/01/2023
Nr Instances: 4
Nr Exposed: 25
Abatement Date:
Gravity: 5
Report ID: 0522300
Contest Date: 02/22/2023
Final Order: 11/27/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/27/2023 | $4,018.00 | Other | ||
Penalty | C: Contested | 11/08/2023 | $10,046.00 | Serious | ||
Penalty | Z: Issued | 02/01/2023 | $10,046.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about November 18, 2022, the employer did not ensure periodic inspections of energy control procedures were being performed at least annually to ensure the requirements of the standard were being followed. The employer did not ensure an inspection was conducted for procedures including but not limited to the Cincinnati Milacron (G99), Knurling (K42, K43), Polisher (E-13), and Polisher (E-06). Hazardous energies present on the equipment include but are not limited to pneumatic, mechanical, electrical, and gravitational energy.