Violation Detail
Standard Cited: 19100146 C01 Permit-required confined spaces
Inspection Nr: 1626813.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $15,625.00
Current Penalty: $15,625.00
Issuance Date: 03/28/2023
Nr Instances: 1
Nr Exposed: 47
Abatement Date: 05/12/2023
Gravity: 10
Report ID: 0830500
Contest Date:
Final Order: 04/20/2023
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/20/2023 | $15,625.00 | 05/12/2023 | Serious | |
Penalty | Z: Issued | 03/28/2023 | $15,625.00 | 04/28/2023 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: a. Carestream Health, Inc., 2000 Howard Smith Ave West, C-40 bldg. Windsor CO 80550: On October 5, 2022 the employer did not evaluate the coil fan room to determine if it was a permit-required confined space. An employee was working inside the coil fan room to repair a leak and was unable to evacuate when the strainer cap broke off releasing hot steam into the room causing the employee to sustain burns to his body. This condition exposed employees to delayed rescue in the event of an injury and burns.