Violation Detail
Standard Cited: 19100147 D05 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1623402.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $10,151.00
Issuance Date: 01/03/2023
Nr Instances: 1
Nr Exposed: 66
Abatement Date: 02/06/2023
Gravity: 10
Report ID: 0418400
Contest Date:
Final Order: 01/24/2023
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/24/2023 | $10,151.00 | 02/06/2023 | Serious | |
| Penalty | Z: Issued | 01/03/2023 | $14,502.00 | 02/06/2023 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(d)(5)(ii): Where there was a possibility of re-accumulation of stored energy to a hazardous level, verification of isolation was not continued until the servicing or maintenance was completed, or until the possibility of such accumulation: a) At 12551 Georgia 273 West, Cedar Springs, GA 39832 on or about September 20, 2022, and at times prior to, the employer exposed employees to burn hazards in that verification of isolation was not completed while performing maintenance during a scheduled outage on blow tank 2.