Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1606228.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,381.00
Current Penalty: $4,500.00
Issuance Date: 12/28/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 04/28/2023
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 01/18/2023
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/18/2023 | $4,500.00 | 04/28/2023 | Serious | |
Penalty | Z: Issued | 12/28/2022 | $6,381.00 | 01/25/2023 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section. a.) Tonnard Manufacturing Corporation, Bay 3 press area, on or about 07/06/2022 and times prior thereto: Employees were performing servicing and maintenance on equipment/machinery that included, but was not limited to, machine #300 250 ton Pacific Hydraulic Press. The lockout/tagout procedures were deficient in that; methods of controlling stored energy were not described, and there was no requirement to verify de-energization prior to initiating work.