Violation Detail
Standard Cited: 19100028 B03 I Duty to have fall protection and falling object protection.
Inspection Nr: 1604943.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,256.00
Current Penalty: $6,153.00
Issuance Date: 12/05/2022
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 01/09/2023
Gravity: 5
Report ID: 0626700
Contest Date:
Final Order: 12/22/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/22/2022 | $6,153.00 | 01/09/2023 | Serious | |
| Penalty | Z: Issued | 12/05/2022 | $10,256.00 | 01/09/2023 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.28(b)(3)(i): The employer did not ensure each employee was protected from falling through any hole (including skylights) that was 4 feet (1.2 m) or more above a lower level by covers, guardrail systems, travel restraint systems, or personal fall arrest systems, as required by sub-items (A) through (D) of this section: a) In the plant, around the Hydro Tester, employees were not protected from falling into a 12-foot by 28-foot rectangular floor hole, approximately 18-foot deep, surrounding the machine.
Translate