Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1583661.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $10,876.00
Issuance Date: 09/06/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/27/2022
Gravity: 10
Report ID: 0523300
Contest Date: 09/30/2022
Final Order: 01/19/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/19/2023 | $10,876.00 | 09/27/2022 | Serious | |
Penalty | C: Contested | 10/05/2022 | $14,502.00 | 09/27/2022 | Serious | |
Penalty | Z: Issued | 09/06/2022 | $14,502.00 | 09/27/2022 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(B):Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; On or about March 9, 2022, the employer did not have an adequate hazardous energy control procedure for the East Mill mix molder machine that required the pneumatic residual air to be bled off, prior to sanitation by the employee, resulting in the unexpected energization of the shuttle head causing an amputation.