Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1567967.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $3,108.00
Current Penalty: $1,980.00
Issuance Date: 02/17/2022
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 03/18/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/18/2022 | $1,980.00 | Serious | ||
Penalty | Z: Issued | 02/17/2022 | $3,108.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about December 10, 2021, the employer failed to ensure employees locking out the Hydraulic Test Stand to change the motor had written developed procedures. The Hydraulic Test Stand has 480 VAC and the hydraulics are under 5000 PSI.