Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1564616.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $10,151.00
Current Penalty: $0.00
Issuance Date: 01/19/2022
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 02/14/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/14/2022 | $0.00 | Serious | ||
| Penalty | Z: Issued | 01/19/2022 | $10,151.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about November 11, 2021, the employer did not ensure procedures for the safe application, usage, and removal of potentially hazardous energy controls were developed, documented, and/or, utilized during die set up on a hydraulic Cunningham Manufacturing Co. "C" style press, S/N 91597-214 with a 6" bore, 3" piston with ?' stroke. The presses contained both electrical and hydraulic stored energy.