Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1563583.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 03/04/2022 2
Initial Penalty: $10,151.00
Current Penalty: $7,100.00
Issuance Date: 02/07/2022
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 10
Report ID: 0830600
Contest Date:
Final Order: 03/03/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/03/2022 | $7,100.00 | 03/04/2022 | Serious | |
Penalty | Z: Issued | 02/07/2022 | $10,151.00 | 03/04/2022 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: (a) On or about November 2, 2021, Hartung Glass Industries did not perform the lock-out/tag-out procedures for the Forvet CNC milling machine, serial # 423/08, by isolating the electrical and pneumatic power sources as required by the company's lockout tagout procedures, located in Hartung Industries Safety Program # 25, resulting in an employee suffering serious injuries while performing maintenance on the machine following a machine malfunction.