Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1560168.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $10,299.00
Current Penalty: $10,299.00
Issuance Date: 11/19/2021
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 01/06/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/06/2022 | $10,299.00 | Serious | ||
Penalty | Z: Issued | 11/19/2021 | $10,299.00 | Repeat |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. On or about October 20, 2021, the employer did not ensure production cooks performing service activities on the filler machine line holding kettle pump, utilized energy control procedures to control the hazardous electrical energy of the pump while removing and cleaning the pump filter screen and/or cleaning the pump's inlet port. Innovative Confection Solutions, LLC., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(4)(i) which was contained in OSHA inspection number 1500587, citation number 1, item number 1 and was affirmed as a final order on February 10, 2021, with respect to a workplace located at 28025 Ranney Parkway, Westlake, Ohio.