Violation Detail
Standard Cited: 19260451 A01 General requirements.
Inspection Nr: 1547404.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,747.00
Current Penalty: $11,747.00
Issuance Date: 01/25/2022
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 01/31/2022
Gravity: 10
Report ID: 0111700
Contest Date:
Final Order: 02/18/2022
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/18/2022 | $11,747.00 | 01/31/2022 | Serious | |
Penalty | Z: Issued | 01/25/2022 | $11,747.00 | 01/31/2022 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.451(a)(1):Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it: Site- On or about August 5, 2021 a carpenter bracket scaffold, made with job made wooden brackets, collapsed when it could not support less than its maximum intended load. Four employees fell to the ground while working from the scaffold when it collapsed.