Violation Detail
Standard Cited: 19100217 C01 I Mechanical power presses.
Inspection Nr: 1542668.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,557.00
Current Penalty: $5,500.00
Issuance Date: 09/13/2021
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 09/20/2021
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 09/30/2021
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/30/2021 | $5,500.00 | 09/20/2021 | Serious | |
| Penalty | Z: Issued | 09/13/2021 | $9,557.00 | 09/20/2021 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.217(c)(1)(i):The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): Dongan Electric Manufacturing Co. dba Pioneer Transformer - Pioneer, Ohio: On or about July 15, 2021, the employer did not ensure employees were protected from amputation injury while operating the #19 Bliss power press. Restraint devices were not properly adjusted for each operation on the power press. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Translate