Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1536196.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $13,653.00
Issuance Date: 09/10/2021
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 11/24/2021
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 10/06/2021
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | 11/11/2021 | $13,653.00 | 10/18/2021 | Serious | |
| Penalty | P: Petition to Mod Abatement | 10/13/2021 | $13,653.00 | 11/24/2021 | Serious | |
| Penalty | I: Informal Settlement | 10/06/2021 | $13,653.00 | 10/18/2021 | Serious | |
| Penalty | Z: Issued | 09/10/2021 | $13,653.00 | 10/18/2021 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; (a) The Fanuc Palletizing Robot Arm (M-710iC, Type: A05B-1125B202), Procedure ALC-LOP070, did not provide specific procedural steps for shutting down, isolating, and releasing the pneumatic energy source exposing employees to accidental/inadvertent restart of the robot. (b) The Quest Tote Filling Conveyor Arm, Procedure ALC-LOP072, did not provide specific procedural steps for shutting down, isolating, and releasing the pneumatic energy source exposing employees to accidental/inadvertent restart of the cheese crane.