Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1511363.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $8,191.00
Issuance Date: 07/13/2021
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 08/16/2021
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 08/05/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/05/2021 | $8,191.00 | 08/16/2021 | Serious | |
| Penalty | Z: Issued | 07/13/2021 | $13,653.00 | 08/16/2021 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) In the facility workshop, on or about January 21, 2021 and at times prior thereto, the procedures to control potentially hazardous energy when Maintenance Technicians (MTs) and Maintenance Assemblers (MAs) connected and disconnected Maxwell MXW4 and MXW6 drill tools to the drill collar roll machines (DCRMs) were not utilized, exposing employees to caught-in and struck-by hazards.