Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1499733.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $9,557.10
Issuance Date: 03/05/2021
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 04/02/2021
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 04/16/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/16/2021 | $9,557.10 | 04/02/2021 | Serious | |
Penalty | Z: Issued | 03/05/2021 | $13,653.00 | 04/02/2021 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(B):Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about October 19, 2020, the employer's energy control procedure for the Roller Mills did not identify specific procedural steps to confirm motion of the rotating mill rolls had been effectively stopped and/or rendered isolated from hazardous energy to ensure employees were protected from in-running nip point hazards.