Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1496180.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,639.00
Current Penalty: $5,300.00
Issuance Date: 12/14/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/04/2021
Gravity: 5
Report ID: 0134000
Contest Date:
Final Order: 01/13/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/13/2021 | $5,300.00 | 01/04/2021 | Serious | |
| Penalty | Z: Issued | 12/14/2020 | $9,639.00 | 01/04/2021 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment Location: 150 Homer Ave, Ashland, MA Printing press#3-Marc Andy printing and rotary dye cutting machine Serial number: 6305 Model number: 43048610Y-27 On or about September 18, 2020, a Marc Andy rotary printing and dye cutting machine (press# 3, serial # 6305, model # 43048610Y-27) was not shut down or deenergized using the procedures established for the machine.