Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1493063.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Not Completed - Solicitor Advised
Initial Penalty: $9,639.00
Current Penalty: $0.00
Issuance Date: 10/14/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/02/2020
Gravity: 5
Report ID: 0729300
Contest Date: 11/03/2020
Final Order: 10/28/2021
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 10/28/2021 | $0.00 | 12/02/2020 | Serious | |
| Penalty | C: Contested | 11/20/2020 | $9,639.00 | 12/02/2020 | Serious | |
| Penalty | Z: Issued | 10/14/2020 | $9,639.00 | 12/02/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: During preventative maintenance planned lubrication of the drive chain to the S2 packaging conveyor, after the guard was removed, the machine was not turned off for lubrication. Abatement documentation is required for this violation.
Translate