Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1480466.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 10/22/2020
Nr Instances: 1
Nr Exposed: 30
Abatement Date: 12/10/2020
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 11/18/2020
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/18/2020 | $0.00 | 12/10/2020 | Serious | |
Penalty | Z: Issued | 10/22/2020 | $13,494.00 | 12/10/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. (a) The employer's written procedures for lock out of the Line 2 extruder were inadequate in that the procedures did not identify which section of the equipment each of the disconnects, E1, E2, E3, E4, E5, and E6, controlled.