Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1477747.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,096.00
Current Penalty: $5,500.00
Issuance Date: 06/25/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/17/2020
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 07/15/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/15/2020 | $5,500.00 | 07/17/2020 | Serious | |
| Penalty | Z: Issued | 06/25/2020 | $8,096.00 | 07/17/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) 1300 Odanah Road; On or about May 11, 2020, the employer did not ensure the use of machine specific energy isolation procedures to control potentially hazardous energy prior to an employee performing jam clearing activities on the Medalist Challoner 900 double-ended tenoner machine.
Translate