Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1474596.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,747.00
Current Penalty: $5,397.60
Issuance Date: 07/14/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/07/2020
Gravity: 5
Report ID: 0215800
Contest Date: 08/04/2020
Final Order: 04/27/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 04/27/2022 | $5,397.60 | 08/07/2020 | Serious | |
| Penalty | C: Contested | 08/05/2020 | $6,747.00 | 08/07/2020 | Serious | |
| Penalty | Z: Issued | 07/14/2020 | $6,747.00 | 08/07/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance. a) In the breast room, on or about 4/22/2020: An employee was cleaning the Multivac machine. Energy control procedures in place did not require authorized employees to perform lockout and tagout on the machines they are assigned to use. Abatement certification must be submitted for this item.