Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1473255.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,145.00
Current Penalty: $11,000.00
Issuance Date: 10/23/2020
Nr Instances: 1
Nr Exposed: 11
Abatement Date: 11/04/2020
Gravity: 10
Report ID: 0215000
Contest Date: 11/18/2020
Final Order: 03/04/2021
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/04/2021 | $11,000.00 | 11/04/2020 | Serious | |
Penalty | C: Contested | 01/06/2021 | $12,145.00 | 11/04/2020 | Serious | |
Penalty | Z: Issued | 10/23/2020 | $12,145.00 | 11/04/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. Location: 3432 Atlantic Ave, Brooklyn, NY. On or about 4/25/2020, a) Lockout/tagout procedures were not utilized by employees when performing maintenance on pressurized air suspension system of a vehicle. Employees were repairing a pressurized air suspension system. A piston from the suspension system dislodged and struck an employee.