Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1461554.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $1,966.00
Current Penalty: $1,966.00
Issuance Date: 05/04/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/29/2020
Gravity: 1
Report ID: 0418200
Contest Date:
Final Order: 06/19/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 05/04/2020 | $1,966.00 | 05/29/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a) Lettuce Processing Area, Lettuce Line Inspection Conveyor: On or about February 1, 2020, an employee in the process of completing cleaning and sanitation operations to the company's food processing equipment located in the lettuce processing area, was exposed to struck-by and caught-in hazards in that the energy control procedures for the Lettuce Line Inspection Conveyor did not clearly and specifically outline the steps for shutting down and isolating hazardous mechanical energy.
Translate