Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1457547.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 08/05/2020 2
Initial Penalty: $13,494.00
Current Penalty: $13,494.00
Issuance Date: 06/30/2020
Nr Instances: 3
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 07/27/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/27/2020 | $13,494.00 | 08/05/2020 | Serious | |
Penalty | Z: Issued | 06/30/2020 | $13,494.00 | 08/05/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(d)(5)(i): The employer did not ensure all potentially hazardous stored or residual energy was relieved, disconnected, restrained, or otherwise rendered safe. On or around January 15, 2020 at the Phillips 66 refinery in Sweeny, Texas the employer did not ensure that potentially hazardous energy was removed before they opened vents on equipment in the Main Fractionator and Overhead System exposing workers to thermal burns, respiratory injury and dermal injuries. a) The employer did not render the energy associated with 95-200 Fractionator Main Fractionator Tower Vent safe. b) Withdrawn c) Withdrawn