Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1450104.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $9,446.00
Current Penalty: $0.00
Issuance Date: 05/14/2020
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 06/09/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection | 
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/09/2020 | $0.00 | Serious | ||
| Penalty | Z: Issued | 05/14/2020 | $9,446.00 | Serious | 
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about December 3, 2019, written procedures for isolation and blanking steam boosters lacked specific steps for isolating coke oven gas in that it did not require lines supplying water to water seal valves to be locked open.