Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1446261.015
Citation: 01001A
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $13,260.00
Current Penalty: $9,282.00
Issuance Date: 01/06/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity:
Report ID: 0522300
Contest Date:
Final Order: 02/07/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/07/2020 | $9,282.00 | Other | ||
| Penalty | Z: Issued | 01/06/2020 | $13,260.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to the following: On or about November 20, 2019, the employer did not ensure the Drum Pump-Drum Change Instruction and the Molteni #3 Mixer energy control procedures clearly and specifically outlined the techniques to be utilized for the control of hazardous energy.