Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1445952.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $4,376.00
Current Penalty: $4,376.00
Issuance Date: 12/09/2019
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 12/19/2019
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 01/08/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 12/09/2019 | $4,376.00 | 12/19/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a. Located at 7263 Lilac Hill Drive, Lot 1285, Plain City, OH 43064: On or about November 20, 2019, employees were exposed to a fall hazard while using a portable step ladder to access the second story to the roof trusses of the residential structure. The ladder did not extend at least three-feet above the second level landing surface of the residential structure.