Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1442637.015
Citation: 01001A
Citation Type: Serious
Abatement Status:
Initial Penalty: $13,359.00
Current Penalty: $0.00
Issuance Date: 02/12/2020
Nr Instances: 1
Nr Exposed: 15
Abatement Date: 03/10/2020
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 03/06/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/06/2020 | $0.00 | 03/10/2020 | Serious | |
Penalty | Z: Issued | 02/12/2020 | $13,359.00 | 03/10/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically outline specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about November 5, 2019, employees perform maintenance and service on various equipment. Employees were exposed to struck by, caught in and amputation hazards in that: a) bag line 3 - The lockout/tagout procedure does not indicate the location of the air valves, how to lock them out and how to verify that they have been deenergized. b) bag line 3- The lockout/tagout procedures does not indicate the location of the main power or how many electrical boxes are needed to be locked out.