Violation Detail
Standard Cited: 19100252 A01 I General requirements.
Inspection Nr: 1428556.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,048.00
Current Penalty: $4,048.00
Issuance Date: 02/24/2020
Nr Instances: 2
Nr Exposed: 4
Abatement Date:
Gravity: 10
Report ID: 0216000
Contest Date:
Final Order: 03/20/2020
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 02/24/2020 | $4,048.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.252(a)(1)(i): When the object to be welded or cut could not be readily moved, all movable fire hazards in the vicinity were not taken to a safe place: On or about and times prior to: 9/4/2019 Location: Bay 2 & Bay 3 a) The employer did not keep torch cutting sparks separate from defueling operations containing flammable gasoline vapors a distance of more than 35 feet to minimize flash back exposing employees to a fire hazard. Removed fuel tanks were hand carried from Bay 2 to Bay 3 and gasoline would spill from cut fuel lines; leaving traces of residual fuel on the ground contributing to the fire hazard.
Translate