Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1424464.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $9,282.00
Issuance Date: 09/25/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 11/29/2019
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 10/29/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/29/2019 | $9,282.00 | 11/29/2019 | Serious | |
| Penalty | Z: Issued | 09/25/2019 | $13,260.00 | 10/18/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. (a) Facility - On or about August 13, 2019 the employer did not ensure procedures specific to each machine were developed, documented and utilized for the control of energy sources of equipment such as but not limited to the kinetic energy with Pillow Blower 17 CCS, when employees performed servicing and maintenance exposing employees to amputation hazards.
Translate