Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1417029.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $13,260.00
Issuance Date: 01/06/2020
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 01/24/2020
Gravity: 10
Report ID: 0317700
Contest Date:
Final Order: 02/04/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/04/2020 | $13,260.00 | 01/24/2020 | Serious | |
Penalty | Z: Issued | 01/06/2020 | $13,260.00 | 01/24/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not used in such a manner as to isolate the machine or equipment from the energy source(s): a) 512 Forest Rd, Hazleton, PA: On or about July 18, 2019, safety blocks for the control of hydraulic movement on the turret of the Nissei One Stage Biaxial Orientation Stretch Blow Molding Machine (#N4) were not used while employees performed servicing and maintenance activities. Abatement Certification and Documentation Required