Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1403627.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Not Completed - Employer Out of Business
Initial Penalty: $5,304.00
Current Penalty: $5,304.00
Issuance Date: 09/30/2019
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 11/04/2019
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 10/28/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 09/30/2019 | $5,304.00 | 11/04/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedures and employee training to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated, and rendered inoperative: On or about May 20, 2019, the employer did not establish an energy control program consisting of energy control procedures, employee training, and periodic inspections to ensure employees performing servicing and maintenance activities on the Cincinnati Press Brake, Amada Vipros 357 punch press, and Trumpf press brake at the facility were protected from unexpected energizing, startup or release of store energy. Machines and equipment used throughout the facility are powered by electric, pneumatic, and hydraulic power.