Violation Detail
Standard Cited: 19100147 C04 II C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1395322.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,210.00
Current Penalty: $10,210.00
Issuance Date: 07/08/2019
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 08/05/2019
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 07/23/2019
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/23/2019 | $10,210.00 | 08/05/2019 | Serious | |
| Penalty | Z: Issued | 07/08/2019 | $10,210.00 | 08/05/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(C): Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and On or about April 19, 2019, employees were exposed to machine hazards associated with moving parts when they were engaged in servicing activities on the Balemaster (Model: 44750-10, G, J, 4, Q, T, U, X, Z, 7,Z, 9; S/N: B0122-04-13389583). The employer did not ensure the energy control procedure, Baler 3500 & Cyclone System/Baler Utility, had specific procedural steps for the transfer of lockout devices.